Te Awamutu, Waipa, Cambridge & Hamilton
Master Electrician · Since 2011105+ Google reviews
0800 263 669
Family relaxing together in a sunlit living room
← All heat pump options
FUJITSU | GENERAL official co-branded logo

NEW ZEALAND’S FAVOURITE AIR®

TE AWAMUTU & WAIPA · SUMMER 2026

Summer
Heat pump
specials.

Cool comfort all summer.
Warmer winters too. Discover installed offers on GENERAL (formerly Fujitsu) heat pumps.

Offers end · Subject to stock availability

Local Master ElectriciansCO Electrical · Established 2011
Back-to-back installationIncluded in every advertised price
Free local site visitsTe Awamutu & within a 15 km radius

A LITTLE EXTRA. MORE EVERYDAY COMFORT.

Why step up to Lifestyle?

Comfort covers the essentials. Lifestyle adds useful control and filtration features, with performance benefits that vary by size. Here’s what your upgrade buys.

Human Sensor control

Detects movement and adjusts operation when the room is unoccupied, helping avoid unnecessary energy use.

Additional filtration

Apple-Catechin and Long-Life Ion Deodorisation filters add dust and odour management to the standard filter arrangement.

Double-swing airflow

Automatic horizontal and vertical louvre movement gives you more control over where conditioned air travels.

More scheduling flexibility

Weekly timer options let you set operation around your routine. Available timer functions depend on the selected controller.

800W more on the 5.0 kW

Upgrade from ASTH18KNTA to ASTH18KMTD and rated heating rises from 5.2 to 6.0 kW. The installed total is $3,550 — just $255 extra.

Model-specific performance

The 2.5 kW Lifestyle reaches 19 dBA in quiet cooling, versus 22 dBA for Comfort. Compare each size below for noise and efficiency figures.

What changes on the three flyer sizes?

Cooling classRated heatingQuiet cooling soundRated heating COP
2.5 kW3.2 kW → 3.2 kW22 → 19 dBA4.16 → 4.84
5.0 kW5.2 kW → 6.0 kW27 → 29 dBA3.91 → 4.69
7.1 kW8.0 kW → 8.0 kW31 → 29 dBA3.85 → 3.92

Figures read Comfort → Lifestyle. Lower dBA means lower sound pressure at the specified quiet setting; higher COP means more heat output per unit of electricity at rated test conditions. Lifestyle is not quieter or more efficient in every mode: the 5.0 kW Comfort has the lower quiet-cooling figure (27 vs 29 dBA), and the 7.1 kW pair has mixed seasonal efficiency results. The 2.5 and 7.1 kW pairs have the same rated heating output. See all specifications ↓

MORE SIZES. THE SAME SUMMER OFFER.

Find your fit.

All 13 Comfort and Lifestyle specials, including the flyer offers. Prices below include GST and standard back-to-back installation.

Cooling and heating capacities are listed separately. In particular, Comfort 3.4 kW offers 4.0 kW rated heating, while Lifestyle 3.5 kW offers 3.7 kW rated heating — we’ll check the right match for your room.

THE DETAILS, WHEN YOU NEED THEM

Full specifications.
Easy to compare.

Open a cooling-size group to compare output, efficiency, energy stars, noise, airflow, dimensions and installation limits. Tables include the manufacturer’s published technical data for the exact model codes.

2.5 kW cooling classASTH09KNCA · ASTH09KMCD

Comfort and Lifestyle compared side by side. Ratings are manufacturer test figures; real output, sound and energy use depend on conditions and settings. Hot / Average / Cold values are climate-zone ratings.

Full manufacturer specifications for ASTH09KNCA and ASTH09KMCD
SpecificationComfort
ASTH09KNCA
Lifestyle
ASTH09KMCD
Special price, installed incl. GST$2,595$2,695
Indoor unitASTH09KNCAASTH09KMCD
Outdoor unitAOTH09KNCAAOTH09KMCD
Operation TypeReverse CycleReverse Cycle
Power Source V/Ph/Hz230 / 1 / 50230 / 1 / 50
Cooling Capacity kW (Rated (Min – Max))2.50 (0.9 – 3.7)2.50 (0.8 – 3.6)
Heating Capacity kW (Rated (Min – Max))3.20 (0.9 – 4.8)3.20 (0.9 – 5.3)
Input Power Cooling kW (Rated (Min – Max))0.59 (0.25 – 1.14)0.53 (0.15 – 1.04)
Input Power Heating kW (Rated (Min – Max))0.77 (0.25 – 1.6)0.66 (0.25 – 1.61)
EER Cooling kW/kW4.244.71
COP Heating kW/kW4.164.84
Star Rating Cooling (0-10) (Hot / Average / Cold)5 / 4.5 / 4.55.5 / 5 / 5.5
Star Rating Heating (0-10) (Hot / Average / Cold)3.5 / 3 / 2.53.5 / 3.5 / 3
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold)6.535 / 6.114 / 6.4767.193 / 6.68 / 7.049
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold)5.235 / 4.625 / 4.0055.455 / 5.025 / 4.533
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold)7.49 / 8.084 / 9.5638.179 / 8.728 / 10.148
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold)5.244 / 4.875 / 4.3395.448 / 5.183 / 4.761
Running Current amps (Cooling / Heating)3 / 3.83 / 3.5
Moisture Removal l/hr11
Indoor Sound Pressure Cooling dBA (High / Quiet)46 / 2240 / 19
Indoor Sound Pressure Heating dBA (High / Quiet)46 / 2740 / 21
Outdoor Sound Pressure dBA (Cooling / Heating)49 / 5146 / 46
Outdoor Sound Power dBA6256
Air Circulation (Indoor – High Fan) Cooling l/sec175194
Air Circulation (Indoor – High Fan) Heating l/sec175197
Indoor Unit Dimensions mm (Height x Width x Depth)270 x 784 x 224270 x 834 x 222
Indoor Unit Weight kg8.0010.00
Outdoor Unit Dimensions mm (Height x Width x Depth)541 x 663 x 290542 x 799 x 290
Outdoor Unit Weight kg25.0032.00
Piping Connects mm Ø (Liquid / Gas)6.35 / 9.526.36 / 9.52
Pipe Length m (Max (Precharged))20 (15)20 (15)
Max Height Difference m1515
Operation Range Cooling °CDB (Min to Max)-10 to 50-10 to 50
Operation Range Heating °CDB (Min to Max)-15 to 24-15 to 24
Refrigerant TypeR32R32
Refrigerant Amount g590850
UART CommunicationYesYes
UART Communication Port2 Ports – CN65, CN752 Ports – CN65, CN75

Source: Manufacturer specifications ↗ · Manufacturer specifications ↗

3.4 / 3.5 kW cooling classASTH12KNCA · ASTH12KMCD

Comfort and Lifestyle compared side by side. Ratings are manufacturer test figures; real output, sound and energy use depend on conditions and settings. Hot / Average / Cold values are climate-zone ratings.

Full manufacturer specifications for ASTH12KNCA and ASTH12KMCD
SpecificationComfort
ASTH12KNCA
Lifestyle
ASTH12KMCD
Special price, installed incl. GST$2,695$2,850
Indoor unitASTH12KNCAASTH12KMCD
Outdoor unitAOTH12KNCAAOTH12KMCD
Operation TypeReverse CycleReverse Cycle
Power Source V/Ph/Hz230 / 1 / 50230 / 1 / 50
Cooling Capacity kW (Rated (Min – Max))3.40 (0.9 – 3.7)3.50 (0.8 – 4.1)
Heating Capacity kW (Rated (Min – Max))4.00 (0.9 – 4.9)3.70 (0.9 – 6.1)
Input Power Cooling kW (Rated (Min – Max))0.96 (0.25 – 1.27)0.86 (0.15 – 1.29)
Input Power Heating kW (Rated (Min – Max))1 (0.25 – 1.52)0.81 (0.25 – 1.89)
EER Cooling kW/kW3.544.07
COP Heating kW/kW44.57
Star Rating Cooling (0-10) (Hot / Average / Cold)4 / 3.5 / 45 / 4.5 / 5
Star Rating Heating (0-10) (Hot / Average / Cold)3 / 2.5 / 23.5 / 3 / 2.5
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold)5.536 / 5.235 / 5.5996.545 / 6.108 / 6.521
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold)4.955 / 4.207 / 3.5075.014 / 4.621 / 4.072
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold)6.182 / 6.603 / 7.5327.613 / 8.312 / 10.07
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold)4.962 / 4.521 / 3.9485.005 / 4.759 / 4.304
Running Current amps (Cooling / Heating)4.8 / 5.14.2 / 4
Moisture Removal l/hr1.21.2
Indoor Sound Pressure Cooling dBA (High / Quiet)40 / 2040 / 19
Indoor Sound Pressure Heating dBA (High / Quiet)42 / 2242 / 21
Outdoor Sound Pressure dBA (Cooling / Heating)50 / 5049 / 49
Outdoor Sound Power dBA6560
Air Circulation (Indoor – High Fan) Cooling l/sec194194
Air Circulation (Indoor – High Fan) Heating l/sec217214
Indoor Unit Dimensions mm (Height x Width x Depth)270 x 834 x 215270 x 834 x 222
Indoor Unit Weight kg9.5010.00
Outdoor Unit Dimensions mm (Height x Width x Depth)541 x 663 x 290542 x 799 x 290
Outdoor Unit Weight kg25.0032.00
Piping Connects mm Ø (Liquid / Gas)6.35 / 9.526.37 / 9.52
Pipe Length m (Max (Precharged))20 (15)20 (15)
Max Height Difference m1515
Operation Range Cooling °CDB (Min to Max)-10 to 50-10 to 50
Operation Range Heating °CDB (Min to Max)-15 to 24-15 to 24
Refrigerant TypeR32R32
Refrigerant Amount g700850
UART CommunicationYesYes
UART Communication Port2 Ports – CN65, CN752 Ports – CN65, CN75

Source: Manufacturer specifications ↗ · Manufacturer specifications ↗

4.2 kW cooling classASTH14KNCA · ASTH14KMCD

Comfort and Lifestyle compared side by side. Ratings are manufacturer test figures; real output, sound and energy use depend on conditions and settings. Hot / Average / Cold values are climate-zone ratings.

Full manufacturer specifications for ASTH14KNCA and ASTH14KMCD
SpecificationComfort
ASTH14KNCA
Lifestyle
ASTH14KMCD
Special price, installed incl. GST$2,895$3,350
Indoor unitASTH14KNCAASTH14KMCD
Outdoor unitAOTH14KNCAAOTH14KMCD
Operation TypeReverse CycleReverse Cycle
Power Source V/Ph/Hz230 / 1 / 50230 / 1 / 50
Cooling Capacity kW (Rated (Min – Max))4.20 (0.9 – 4.4)4.20 (0.9 – 4.5)
Heating Capacity kW (Rated (Min – Max))4.70 (0.9 – 5.8)5.40 (0.9 – 6.9)
Input Power Cooling kW (Rated (Min – Max))1.23 (0.25 – 1.4)1.15 (0.25 – 1.25)
Input Power Heating kW (Rated (Min – Max))1.13 (0.25 – 1.73)1.4 (0.25 – 2.05)
EER Cooling kW/kW3.413.65
COP Heating kW/kW4.163.86
Star Rating Cooling (0-10) (Hot / Average / Cold)4 / 3.5 / 44 / 4 / 4
Star Rating Heating (0-10) (Hot / Average / Cold)3.5 / 3 / 23.5 / 2.5 / 2
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold)5.55 / 5.262 / 5.6915.834 / 5.513 / 5.926
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold)5.25 / 4.54 / 3.8015.09 / 4.383 / 3.677
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold)6.165 / 6.593 / 7.476.511 / 6.962 / 7.93
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold)5.26 / 4.825 / 4.1915.105 / 4.676 / 4.06
Running Current amps (Cooling / Heating)5.9 / 5.65.1 / 6.2
Moisture Removal l/hr1.61.6
Indoor Sound Pressure Cooling dBA (High / Quiet)43 / 2044 / 20
Indoor Sound Pressure Heating dBA (High / Quiet)44 / 2445 / 24
Outdoor Sound Pressure dBA (Cooling / Heating)50 / 5050 / 50
Outdoor Sound Power dBA6565
Air Circulation (Indoor – High Fan) Cooling l/sec214214
Air Circulation (Indoor – High Fan) Heating l/sec228228
Indoor Unit Dimensions mm (Height x Width x Depth)270 x 834 x 215270 x 834 x 222
Indoor Unit Weight kg10.0010.00
Outdoor Unit Dimensions mm (Height x Width x Depth)542 x 799 x 290632 x 799 x 290
Outdoor Unit Weight kg31.0034.00
Piping Connects mm Ø (Liquid / Gas)6.35 / 9.526.38 / 9.52
Pipe Length m (Max (Precharged))20 (15)20 (15)
Max Height Difference m1515
Operation Range Cooling °CDB (Min to Max)-10 to 50-10 to 50
Operation Range Heating °CDB (Min to Max)-15 to 24-15 to 24
Refrigerant TypeR32R32
Refrigerant Amount g850940
UART CommunicationYesYes
UART Communication Port2 Ports – CN65, CN752 Ports – CN65, CN75

Source: Manufacturer specifications ↗ · Manufacturer specifications ↗

5.0 kW cooling classASTH18KNTA · ASTH18KMTD

Comfort and Lifestyle compared side by side. Ratings are manufacturer test figures; real output, sound and energy use depend on conditions and settings. Hot / Average / Cold values are climate-zone ratings.

Full manufacturer specifications for ASTH18KNTA and ASTH18KMTD
SpecificationComfort
ASTH18KNTA
Lifestyle
ASTH18KMTD
Special price, installed incl. GST$3,295$3,550
Indoor unitASTH18KNTAASTH18KMTD
Outdoor unitAOTH18KNTAAOTH18KMTD
Operation TypeReverse CycleReverse Cycle
Power Source V/Ph/Hz230 / 1 / 50230 / 1 / 50
Cooling Capacity kW (Rated (Min – Max))5.00 (0.9 – 5.6)5.00 (1 – 6.5)
Heating Capacity kW (Rated (Min – Max))5.20 (0.9 – 7)6.00 (1.05 – 8.7)
Input Power Cooling kW (Rated (Min – Max))1.44 (0.14 – 1.74)1.16 (0.24 – 1.93)
Input Power Heating kW (Rated (Min – Max))1.33 (0.12 – 2.17)1.28 (0.14 – 2.75)
EER Cooling kW/kW3.474.31
COP Heating kW/kW3.914.69
Star Rating Cooling (0-10) (Hot / Average / Cold)3.5 / 3.5 / 3.55 / 4.5 / 5
Star Rating Heating (0-10) (Hot / Average / Cold)3 / 2.5 / 23.5 / 3 / 2.5
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold)5.395 / 5.122 / 5.4916.652 / 6.3 / 6.726
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold)4.961 / 4.28 / 3.5755.004 / 4.676 / 4.181
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold)5.911 / 6.244 / 6.9337.428 / 7.934 / 9.086
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold)4.97 / 4.554 / 3.9484.631 / 4.393 / 4.376
Running Current amps (Cooling / Heating)6.4 / 5.85.3 / 5.8
Moisture Removal l/hr2.31.3
Indoor Sound Pressure Cooling dBA (High / Quiet)46 / 2746 / 29
Indoor Sound Pressure Heating dBA (High / Quiet)46 / 2946 / 29
Outdoor Sound Pressure dBA (Cooling / Heating)49 / 4947 / 49
Outdoor Sound Power dBA6159
Air Circulation (Indoor – High Fan) Cooling l/sec225283
Air Circulation (Indoor – High Fan) Heating l/sec225286
Indoor Unit Dimensions mm (Height x Width x Depth)270 x 834 x 232280 x 980 x 240
Indoor Unit Weight kg11.0012.50
Outdoor Unit Dimensions mm (Height x Width x Depth)542 x 799 x 290716 x 820 x 315
Outdoor Unit Weight kg33.0042.00
Piping Connects mm Ø (Liquid / Gas)6.35 / 12.76.35 / 12.7
Pipe Length m (Max (Precharged))25 (15)30 (15)
Max Height Difference m2025
Operation Range Cooling °CDB (Min to Max)-10 to 50-10 to 50
Operation Range Heating °CDB (Min to Max)-15 to 24-15 to 24
Refrigerant TypeR32R32
Refrigerant Amount g8901,270
UART CommunicationYesYes
UART Communication Port2 Ports – CN65, CN752 Ports – CN65, CN75

Source: Manufacturer specifications ↗ · Manufacturer specifications ↗

6.0 kW cooling classASTH22KNTA · ASTH22KMTD

Comfort and Lifestyle compared side by side. Ratings are manufacturer test figures; real output, sound and energy use depend on conditions and settings. Hot / Average / Cold values are climate-zone ratings.

Full manufacturer specifications for ASTH22KNTA and ASTH22KMTD
SpecificationComfort
ASTH22KNTA
Lifestyle
ASTH22KMTD
Special price, installed incl. GST$3,450$3,950
Indoor unitASTH22KNTAASTH22KMTD
Outdoor unitAOTH22KNTAAOTH22KMTD
Operation TypeReverse CycleReverse Cycle
Power Source V/Ph/Hz230 / 1 / 50230 / 1 / 50
Cooling Capacity kW (Rated (Min – Max))6.00 (0.9 – 6.5)6.00 (1.1 – 7.5)
Heating Capacity kW (Rated (Min – Max))6.50 (0.9 – 7.7)7.20 (1.1 – 9.4)
Input Power Cooling kW (Rated (Min – Max))1.78 (0.12 – 2.07)1.58 (0.24 – 2.72)
Input Power Heating kW (Rated (Min – Max))1.85 (0.12 – 2.4)1.7 (0.14 – 2.75)
EER Cooling kW/kW3.373.8
COP Heating kW/kW3.514.24
Star Rating Cooling (0-10) (Hot / Average / Cold)3.5 / 3.5 / 3.54.5 / 4 / 4.5
Star Rating Heating (0-10) (Hot / Average / Cold)3 / 2 / 1.53 / 2.5 / 2
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold)5.963 / 6.36 / 7.1876.009 / 5.714 / 6.146
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold)4.901 / 3.982 / 3.2684.64 / 4.258 / 3.722
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold)5.377 / 5.101 / 5.4956.672 / 7.138 / 8.111
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold)4.922 / 4.379 / 3.5994.631 / 4.393 / 3.951
Running Current amps (Cooling / Heating)7.9 / 8.27.1 / 7.7
Moisture Removal l/hr2.92.3
Indoor Sound Pressure Cooling dBA (High / Quiet)48 / 3148 / 29
Indoor Sound Pressure Heating dBA (High / Quiet)48 / 3148 / 29
Outdoor Sound Pressure dBA (Cooling / Heating)54 / 5349 / 52
Outdoor Sound Power dBA6861
Air Circulation (Indoor – High Fan) Cooling l/sec244294
Air Circulation (Indoor – High Fan) Heating l/sec244300
Indoor Unit Dimensions mm (Height x Width x Depth)270 x 834 x 232280 x 980 x 240
Indoor Unit Weight kg11.0012.50
Outdoor Unit Dimensions mm (Height x Width x Depth)632 x 799 x 290716 x 820 x 315
Outdoor Unit Weight kg36.0042.00
Piping Connects mm Ø (Liquid / Gas)6.35 / 12.76.35 / 12.7
Pipe Length m (Max (Precharged))25 (15)30 (15)
Max Height Difference m2025
Operation Range Cooling °CDB (Min to Max)-10 to 50-10 to 50
Operation Range Heating °CDB (Min to Max)-15 to 24-15 to 24
Refrigerant TypeR32R32
Refrigerant Amount g9601,270
UART CommunicationYesYes
UART Communication Port2 Ports – CN65, CN752 Ports – CN65, CN75

Source: Manufacturer specifications ↗ · Manufacturer specifications ↗

7.1 kW cooling classASTH24KNTA · ASTH24KMTE

Comfort and Lifestyle compared side by side. Ratings are manufacturer test figures; real output, sound and energy use depend on conditions and settings. Hot / Average / Cold values are climate-zone ratings.

Full manufacturer specifications for ASTH24KNTA and ASTH24KMTE
SpecificationComfort
ASTH24KNTA
Lifestyle
ASTH24KMTE
Special price, installed incl. GST$3,995$4,195
Indoor unitASTH24KNTAASTH24KMTE
Outdoor unitAOTH24KNTAAOTH24KMTE
Operation TypeReverse CycleReverse Cycle
Power Source V/Ph/Hz230 / 1 / 50230 / 1 / 50
Cooling Capacity kW (Rated (Min – Max))7.10 (1 – 8)7.10 (1.1 – 8.3)
Heating Capacity kW (Rated (Min – Max))8.00 (1 – 9.6)8.00 (1.1 – 10.1)
Input Power Cooling kW (Rated (Min – Max))2.2 (0.16 – 3)2.2 (0.24 – 3.15)
Input Power Heating kW (Rated (Min – Max))2.08 (0.16 – 2.74)2.04 (0.14 – 3.17)
EER Cooling kW/kW3.233.23
COP Heating kW/kW3.853.92
Star Rating Cooling (0-10) (Hot / Average / Cold)3.5 / 3 / 3.53.5 / 3.5 / 4
Star Rating Heating (0-10) (Hot / Average / Cold)3.5 / 2.5 / 23.5 / 2 / 2.5
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold)5.639 / 5.982 / 6.665.344 / 5.094 / 5.481
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold)5.329 / 4.407 / 3.5734.819 / 4.265 / 3.586
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold)5.143 / 4.897 / 5.2885.873 / 6.231 / 6.897
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold)5.35 / 4.779 / 4.0474.817 / 4.474 / 3.909
Running Current amps (Cooling / Heating)9.6 / 9.29.8 / 9.3
Moisture Removal l/hr3.22.7
Indoor Sound Pressure Cooling dBA (High / Quiet)50 / 3149 / 29
Indoor Sound Pressure Heating dBA (High / Quiet)48 / 3149 / 29
Outdoor Sound Pressure dBA (Cooling / Heating)55 / 5654 / 53
Outdoor Sound Power dBA6766
Air Circulation (Indoor – High Fan) Cooling l/sec336325
Air Circulation (Indoor – High Fan) Heating l/sec311331
Indoor Unit Dimensions mm (Height x Width x Depth)280 x 980 x 240280 x 980 x 240
Indoor Unit Weight kg12.5012.50
Outdoor Unit Dimensions mm (Height x Width x Depth)632 x 799 x 290716 x 820 x 315
Outdoor Unit Weight kg39.0042.00
Piping Connects mm Ø (Liquid / Gas)6.35 / 12.76.35 / 12.7
Pipe Length m (Max (Precharged))30 (15)30 (15)
Max Height Difference m2525
Operation Range Cooling °CDB (Min to Max)-10 to 50-10 to 50
Operation Range Heating °CDB (Min to Max)-15 to 24-15 to 24
Refrigerant TypeR32R32
Refrigerant Amount g1,2001,270
UART CommunicationYesYes
UART Communication Port2 Ports – CN65, CN752 Ports – CN65, CN75

Source: Manufacturer specifications ↗ · Manufacturer specifications ↗

8.5 kW cooling classASTH30KNTA

Comfort model. Ratings are manufacturer test figures; real output, sound and energy use depend on conditions and settings. Hot / Average / Cold values are climate-zone ratings.

Full manufacturer specifications for ASTH30KNTA
SpecificationComfort
ASTH30KNTA
Special price, installed incl. GST$4,499
Indoor unitASTH30KNTA
Outdoor unitAOTH30KNTA
Operation TypeReverse Cycle
Power Source V/Ph/Hz230 / 1 / 50
Cooling Capacity kW (Rated (Min – Max))8.50 (2.9 – 10.5)
Heating Capacity kW (Rated (Min – Max))9.00 (2.7 – 11.2)
Input Power Cooling kW (Rated (Min – Max))2.49 (0.6 – 4)
Input Power Heating kW (Rated (Min – Max))2.39 (0.48 – 3.6)
EER Cooling kW/kW3.41
COP Heating kW/kW3.77
Star Rating Cooling (0-10) (Hot / Average / Cold)4 / 3.5 / 4
Star Rating Heating (0-10) (Hot / Average / Cold)4 / 3 / 2
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold)5.56 / 5.284 / 5.716
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold)5.55 / 4.534 / 3.841
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold)6.233 / 6.729 / 7.766
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold)5.611 / 5.02 / 4.353
Running Current amps (Cooling / Heating)11 / 10.6
Moisture Removal l/hr4.4
Indoor Sound Pressure Cooling dBA (High / Quiet)51 / 32
Indoor Sound Pressure Heating dBA (High / Quiet)48 / 32
Outdoor Sound Pressure dBA (Cooling / Heating)53 / 55
Outdoor Sound Power dBA65
Air Circulation (Indoor – High Fan) Cooling l/sec381
Air Circulation (Indoor – High Fan) Heating l/sec350
Indoor Unit Dimensions mm (Height x Width x Depth)340 x 1150 x 280
Indoor Unit Weight kg16.50
Outdoor Unit Dimensions mm (Height x Width x Depth)788 x 940 x 320
Outdoor Unit Weight kg53.00
Piping Connects mm Ø (Liquid / Gas)9.52 / 15.88
Pipe Length m (Max (Precharged))30 (20)
Max Height Difference m20
Operation Range Cooling °CDB (Min to Max)-10 to 50
Operation Range Heating °CDB (Min to Max)-15 to 24
Refrigerant TypeR32
Refrigerant Amount g1,700
UART CommunicationYes
UART Communication Port2 Ports – CN65, CN75

Source: Manufacturer specifications ↗

Manufacturer data checked 22 October 2026. Capacity is heat delivered or removed, not electrical consumption. Star ratings vary by climate zone. Maximum refrigerant pipe lengths in these tables are technical limits, not the pipework allowance included in the advertised installation. Specifications are subject to manufacturer changes; final selection is confirmed in your written quote.

FROM FIRST LOOK TO FINAL FIT

Let’s get your home comfortable.

01

Tell us about your room.

Choose an offer or ask for help. Tell us your location, room size and how you use the space.

02

We check your installation.

A site visit confirms sizing, unit placement, pipe route and electrical requirements. Visits are free in Te Awamutu and within a 15 km radius.

03

You receive a written quote.

We confirm the final installed price and any extra work before you decide to proceed.

Clear prices.
Clear conditions.

A standard back-to-back installation places the indoor unit on an external wall, with the outdoor unit immediately outside. Site conditions determine the final installation plan.

  • Specials are available until 30 November 2026, subject to stock availability.
  • All advertised prices are in NZD, include GST and apply to standard back-to-back installation only.
  • A site visit is required to confirm suitability and final price. A written quote will set out the agreed work and any extras.
  • Site visits are free in Te Awamutu and within a 15 km radius. For locations beyond that area, any site-visit charge will be confirmed before booking.
  • Non-standard pipe routes, difficult access, drainage changes, mounting requirements and additional electrical work may cost extra and will be quoted separately.
  • Wi-Fi control requires a compatible optional module and costs extra. Manufacturer warranty terms apply to the selected equipment.
  • Read our standard back-to-back installation terms and conditions. Any promotion-specific inclusions will be confirmed in your written quote.

YOUR LOCAL ELECTRICAL EXPERTS

Ready for a cooler summer?

Talk to Chris and the CO Electrical team about the right GENERAL heat pump for your home. Mention the Summer Heat Pump Specials when you enquire.

Arrange a site visit 0800 263 669Free site visits: Te Awamutu & within 15 km.
View the final Summer Heat Pump Specials flyerSummer flyer: Comfort 2.5 kW $2,595; 5.0 kW $3,295; 7.1 kW $3,995 installed including GST, subject to terms. Lifestyle upgrades $200, $255 and $200 respectively.

Current 2.5 kW Lifestyle offer: $2,695 installed — $100 above Comfort. This replaces the +$200 upgrade printed on the flyer.